Skip to content
AL solutions

Flammable Refrigerant Safety Assessment

Flammable refrigerant safety assessment measures, to international standards, whether a leak from a product using a flammable A2L or A3 refrigerant such as R-32 or R-290 brings the concentration in air up to the lower flammability limit (LFL), and whether any nearby part could ignite it. AL solutions reports the measurement data and the reasoning behind each judgment.

Flammable Refrigerant Lab

Dedicated flammable
refrigerant lab

  • Dedicated to flammable refrigerants

    Test facilities and engineers focused on A2L/A3 leak and concentration measurement and ignition source assessment.

  • Six product standards

    From tumble dryers to professional ice-cream makers — six parts of the IEC 60335-2 series under one roof.

  • Reports that hold up

    Measurement data and rationale in a report you can use for Korean and overseas certification.

A1, A2L, A3: every refrigerant carries a different risk

Refrigerants are classed by flammability as A1 (non-flammable), A2L (mildly flammable) and A3 (highly flammable). Once the concentration in air exceeds the lower flammability limit (LFL), it can ignite — so the lower the LFL, the smaller the leak that becomes dangerous.

That is why an assessment looks at the charge in the product, the concentration after a leak, and whether any part nearby could create a spark.

We test six flammable refrigerants: R-32, R-454B, R-454C, R-455A, R-290, R-600a.

R-32

Difluoromethane

Safety class A2L

Mildly flammable. Can ignite, but burns slowly (10 cm/s or less).

Refrigerant concentration in air (%vol)Can ignite from LFL 14.4%
0481216
LFL (mass)
0.307 kg/m³
Global warming potential (GWP)
675
Typical use
Residential & commercial air conditioners, heat pumps

Representative values from public sources such as ISO 817 and ASHRAE 34. Actual tests use values for the test conditions.

Six flammable refrigerants compared — safety class, lower flammability limit (LFL), global warming potential (GWP)
RefrigerantCompositionSafety classLFL (%vol)LFL (kg/m³)GWPTypical use
R-32DifluoromethaneA2LMildly flammable. Can ignite, but burns slowly (10 cm/s or less).14.40.307675Residential & commercial air conditioners, heat pumps
R-454BR-32 / R-1234yf blendA2LMildly flammable. Can ignite, but burns slowly (10 cm/s or less).11.80.296466Packaged air conditioners, chillers, heat pumps
R-454CR-32 / R-1234yf blendA2LMildly flammable. Can ignite, but burns slowly (10 cm/s or less).7.70.293148Commercial refrigeration, heat pumps
R-455AR-32 / R-1234yf / CO₂ blendA2LMildly flammable. Can ignite, but burns slowly (10 cm/s or less).11.80.431148Commercial refrigeration, heat pumps
R-290PropaneA3Highly flammable. Even a small leak carries ignition risk, so charge and ignition sources are tightly controlled.2.10.0383Showcases, small refrigeration, heat pumps
R-600aIsobutaneA3Highly flammable. Even a small leak carries ignition risk, so charge and ignition sources are tightly controlled.1.80.0433Household refrigerators

Safety class and LFL are representative values from public sources such as ISO 817 and ASHRAE 34; GWP is the IPCC AR4 100-year value. Actual tests use values for the test conditions.

Flammable refrigerant rules in product safety standards

Korea's KC 60335 safety standards treat flammable refrigerants differently for each product.

  • Air conditioners, heat pumps, dehumidifiers — KC 60335-2-40

    Charge limits are set in bands (m1, m2, m3) obtained by multiplying the refrigerant's LFL (kg/m³) by fixed volumes, which determine the allowed charge and installation space. A3 refrigerants use 4, 26 and 130 m³, and A2L refrigerants use 6, 52 and 260 m³, multiplied by the LFL.

    IEC 60335-2-40: Flammable Refrigerant Test Items
  • Household refrigerators, freezers, ice makers — KC 60335-2-24

    Limits flammable refrigerant to 150 g or less per circuit.

    KC Certification for R-600a Products
  • Commercial refrigerating appliances, showcases — KC 60335-2-89

    Excludes appliances that need 150 g or more of flammable refrigerant per circuit.

    IEC 60335-2-89: Flammable Refrigerant Test Items
  • Tumble dryers (heat pump) — KC 60335-2-11

    Does not allow more than 150 g of flammable refrigerant per circuit.

    KC Certification for R-290 Products

Sources: KC 60335-2-40 (KATS Notice 2022-0105) Annex GG, KC 60335-2-24 (Notice 2025-0402) 22.106, KC 60335-2-89 (Notice 2015-286) Note 104, KC 60335-2-11 (Notice 2021-0031) 22.201 · checked 2026-11-03

Products we test

Applicable standards for each product, in standard-number order.

Products and applicable standards
StandardProducts
IEC 60335-2-11Tumble dryers (heat pump)
IEC 60335-2-24Household refrigerators, freezers, ice makers
IEC 60335-2-40Air conditioners, heat pumps, dehumidifiers
IEC 60335-2-89Commercial refrigerating appliances, showcases
IEC 60335-2-104Refrigerant recovery & recycling equipment
IEC 60335-2-118Professional ice-cream makers

Also referenced: ISO 5149 (Safety of refrigerating systems and heat pumps), ISO 817 (Refrigerant designation and safety classification)

Refrigerant test rig with pressure gauges, copper piping and a compressor

No documents yet? You can still start.

A consultant will get back to you within one business day. We'll tell you the certification category, required tests and expected timeline first.