Skip to content
AL solutions

KC Certification for R-600a Products

R-600a (isobutane) is a highly flammable A3 refrigerant used mainly in household refrigerators. Household refrigerators and freezers (rated input up to 1.5 kW) are a KC Safety Certification item, and Korea's KC 60335-2-24 limits flammable refrigerant to 150 g or less per circuit.

What is checked for KC certification and safety testing

  • Charge review — maximum charge and minimum installation area for the refrigerant and room size
  • Leak test and concentration measurement — reproduce a leak and compare the surrounding concentration with the LFL
  • Ignition source assessment — location and temperature of arcing parts and hot surfaces
  • Safety measures — leak detection, circulation/ventilation fans and shut-off devices
  • Refrigerant circuit tightness — joints, pressure and tightness tests
  • Markings and manuals — flammable refrigerant warnings and installation/service instructions

See also: Six flammable refrigerants compared · Case studies (Korean)

Sources: Safety class & LFL: ISO 817 representative values; GWP: IPCC AR4 / Category: KATS operating notice Appendix 1 / Standard: KC 60335-2-24 (KATS Notice 2025-0402) 22.106 (checked November 3, 2026). Content may change when regulations or standards are amended.

No documents yet? You can still start.

A consultant will get back to you within one business day. We'll tell you the certification category, required tests and expected timeline first.

+82-2-3159-9062official@apx-lab.comMon–Fri 09:00–18:00 KST (lunch 12:00–13:00)