IEC 60335-2-89: Flammable Refrigerant Test Items
IEC 60335-2-89 is the safety standard for commercial refrigerating appliances such as showcases and ice makers. Korea's KC 60335-2-89 (KATS Notice 2015-286) is based on the 2012 edition (Ed. 2.1) and excludes appliances that need 150 g or more of flammable refrigerant per circuit. The current IEC edition is the 2019 edition (Ed. 3).
How AL solutions' test items map
- Charge review — maximum charge and minimum installation area for the refrigerant and room size
- Leak test and concentration measurement — reproduce a leak and compare the surrounding concentration with the LFL
- Ignition source assessment — location and temperature of arcing parts and hot surfaces
- Safety measures — leak detection, circulation/ventilation fans and shut-off devices
- Refrigerant circuit tightness — joints, pressure and tightness tests
- Markings and manuals — flammable refrigerant warnings and installation/service instructions
See also: KC Certification for R-290 Products · Six flammable refrigerants compared · Case studies (Korean)
Sources: KC 60335-2-89 (KATS Notice 2015-286) Note 104 / IEC 60335-2-89:2019 (IEC webstore) (checked November 3, 2026). Content may change when regulations or standards are amended.