KC Certification for R-290 Products
R-290 (propane) is a highly flammable A3 refrigerant used in showcases, small refrigerating appliances and heat pumps. Because even a small leak is hazardous, the charge is tightly controlled. Korea's KC 60335-2-89 (commercial refrigeration) excludes appliances that need 150 g or more of flammable refrigerant per circuit, and KC 60335-2-11 (heat-pump tumble dryers) does not allow more than 150 g per circuit.
What is checked for KC certification and safety testing
- Charge review — maximum charge and minimum installation area for the refrigerant and room size
- Leak test and concentration measurement — reproduce a leak and compare the surrounding concentration with the LFL
- Ignition source assessment — location and temperature of arcing parts and hot surfaces
- Safety measures — leak detection, circulation/ventilation fans and shut-off devices
- Refrigerant circuit tightness — joints, pressure and tightness tests
- Markings and manuals — flammable refrigerant warnings and installation/service instructions
See also: IEC 60335-2-89: Flammable Refrigerant Test Items · Six flammable refrigerants compared · Case studies (Korean)
Sources: Safety class & LFL: ISO 817 representative values; GWP: IPCC AR4 / Standards: KC 60335-2-89 (KATS Notice 2015-286) Note 104, KC 60335-2-11 (Notice 2021-0031) 22.201 (checked November 3, 2026). Content may change when regulations or standards are amended.